Kernel driver tps53679¶
Supported chips:
Texas Instruments TPS53647
Prefix: ‘tps53647’
Addresses scanned: -
Datasheet: http://www.ti.com/lit/gpn/tps53647
Texas Instruments TPS53667
Prefix: ‘tps53667’
Addresses scanned: -
Datasheet: http://www.ti.com/lit/gpn/TPS53667
Texas Instruments TPS53679
Prefix: ‘tps53679’
Addresses scanned: -
Datasheet: http://www.ti.com/lit/gpn/TPS53679 (short version)
Texas Instruments TPS53681
Prefix: ‘tps53681’
Addresses scanned: -
Datasheet: http://www.ti.com/lit/gpn/TPS53681
Texas Instruments TPS53688
Prefix: ‘tps53688’
Addresses scanned: -
Datasheet: Available under NDA
- Authors:
Vadim Pasternak <vadimp@mellanox.com> Guenter Roeck <linux@roeck-us.net>
Description¶
Chips in this series are multi-phase step-down converters with one or two output channels and up to 8 phases per channel.
Usage Notes¶
This driver does not probe for PMBus devices. You will have to instantiate devices explicitly.
Example: the following commands will load the driver for an TPS53681 at address 0x60 on I2C bus #1:
# modprobe tps53679
# echo tps53681 0x60 > /sys/bus/i2c/devices/i2c-1/new_device
Sysfs attributes¶
in1_label |
“vin” |
in1_input |
Measured input voltage. |
in1_lcrit |
Critical minimum input voltage TPS53679, TPS53681, TPS53688 only. |
in1_lcrit_alarm |
Input voltage critical low alarm. TPS53679, TPS53681, TPS53688 only. |
in1_crit |
Critical maximum input voltage. |
in1_crit_alarm |
Input voltage critical high alarm. |
in[N]_label |
“vout[1-2]”
|
in[N]_input |
Measured output voltage. |
in[N]_lcrit |
Critical minimum input voltage. TPS53679, TPS53681, TPS53688 only. |
in[N]_lcrit_alarm |
Critical minimum voltage alarm. TPS53679, TPS53681, TPS53688 only. |
in[N]_alarm |
Output voltage alarm. TPS53647, TPS53667 only. |
in[N]_crit |
Critical maximum output voltage. TPS53679, TPS53681, TPS53688 only. |
in[N]_crit_alarm |
Output voltage critical high alarm. TPS53679, TPS53681, TPS53688 only. |
temp[N]_input |
Measured temperature.
|
temp[N]_max |
Maximum temperature. |
temp[N]_crit |
Critical high temperature. |
temp[N]_max_alarm |
Temperature high alarm. |
temp[N]_crit_alarm |
Temperature critical high alarm. |
power1_label |
“pin”. |
power1_input |
Measured input power. |
power[N]_label |
“pout[1-2]”.
|
power[N]_input |
Measured output power. |
curr1_label |
“iin”. |
curr1_input |
Measured input current. |
curr1_max |
Maximum input current. |
curr1_max_alarm |
Input current high alarm. |
curr1_crit |
Critical input current. |
curr1_crit_alarm |
Input current critical alarm. |
curr[N]_label |
“iout[1-2]” or “iout1.[0-5]”. The first digit is the output channel, the second digit is the phase within the channel. Per-phase telemetry supported on TPS53681 only.
|
curr[N]_input |
Measured output current. |
curr[N]_max |
Maximum output current. |
curr[N]_crit |
Critical high output current. |
curr[N]_max_alarm |
Output current high alarm. |
curr[N]_crit_alarm |
Output current critical high alarm. Limit and alarm attributes are only available for non-phase telemetry (iout1, iout2). |